It is a busy month and you are on the last week with a heavy workload left of PMs (preventative maintenance) to perform and you receive a call from the NICU (neonate intensive care unit) about a broke Nursing Assignment Help

It is a busy month and you are on the last week with a heavy workload left of PMs (preventative maintenance) to perform and you receive a call from the NICU (neonate intensive care unit) about a broken radiant warmer. It is an urgent call because there have been many births and there are no spare radiant warmers available so this one must be fixed right away. Upon examining the warmer, you pop the back panel off to expose the circuitry and find that a Molex connector had come loose and was not delivering power from the power supply block to the mainboard of the unit. After firmly reseating the connection you replace the back panel and power the unit on to do a quick PM in order to verify that it is working properly and that it is safe for patient use. The unit passed all functional tests with flying colors, however, while performing the PM you notice that there was a slight flicker every few minutes on the display of the unit where the temperature and timer are shown. The NICU nurse who made the call sees that you have finished testing the unit and approaches you asking if the unit is fixed and ready to be put back into service to be used on a newborn infant.

  1. Read and Analyze the scenario.
  2. For your initial post, let us know what you would do in this situation.
    • Would you sign off the incubator as ‘mission ready and capable’? (explain why or why not)
    • In a dialog format (using your own words), let us how you would explain the situation to the NICU nurse.

Expert Solution Preview

Introduction:

In this scenario, a medical professor is faced with a situation where a broken radiant warmer in the neonate intensive care unit (NICU) needs to be fixed urgently. After examining the warmer and reseating a loose Molex connector, the unit appears to be working properly during functional tests. However, a slight flicker on the display is observed during a preventative maintenance (PM) check. The medical professor now needs to decide whether to sign off the unit as ‘mission ready and capable’ and how to explain the situation to the NICU nurse.

1. Read and Analyze the scenario:

The scenario describes a broken radiant warmer in the NICU that needs to be fixed urgently. After reseating a loose Molex connector, the unit passes all functional tests but exhibits a slight flicker on the display during PM. The medical professor needs to assess the implications of the flicker and determine if it poses any risk to patient safety.

2. What would you do in this situation?

In this situation, I would not sign off the incubator as ‘mission ready and capable’ immediately. Although the unit passed all functional tests, the flicker observed on the display during the PM raises concerns about its long-term reliability and potential impact on patient care.

The flickering display could indicate an underlying intermittent electrical issue or a faulty component within the unit. Given the critical nature of neonatal care and the potential consequences of equipment malfunctions, it is essential to prioritize patient safety above expediency.

Therefore, I would inform the NICU nurse that while the initial problem with the Molex connector has been fixed, a new issue has been observed during the PM. Explaining that the flicker on the display raises concerns about the unit’s reliability, I would propose the following course of action:

In the interest of patient safety, it is necessary to conduct further investigation and perform additional testing to identify the cause of the flickering display. This will help ensure that the unit is fully functional and safe for use on a newborn infant. I would suggest contacting the manufacturer or a specialized biomedical technician to thoroughly assess and evaluate the radiant warmer.

By taking these additional measures, we can be confident that the unit is not only fixed but also reliable, reducing the risk of any potential harm to the newborn infant. Our top priority must always be the well-being and safety of our patients.

In summary, I would not sign off the incubator as ‘mission ready and capable’ due to the observed flicker on the display. Instead, I would communicate the need for further investigation and testing to ensure patient safety to the NICU nurse.

Share This Post

Email
WhatsApp
Facebook
Twitter
LinkedIn
Pinterest
Reddit

Order a Similar Paper and get 15% Discount on your First Order

Related Questions

Technology for Patient Safety in Saudi Arabia Paper Nursing Assignment Help

You are the manager of a busy hospital unit.  Your unit has been tasked with selecting and implementing upgraded technology on your hospital unit.  As the unit manger, address the following in your selection of technology and implementation plan: Examine the features of the new technology that are important in

WU Detail and Dynamic Complexity Discussion Nursing Assignment Help

Are you overwhelmed by complexity? If so, you are not alone. Peter Senge notes that people are now able to “create far more information that anyone can absorb,” and he continues to say that the “scale of complexity is without precedent” (2006, p. 69). This “detail” complexity can make managing

Pediatric Health & Medical Worksheet Nursing Assignment Help

Provider: i. Questions for HPI When did these symptoms begin? Is the child experience exercise intolerance? Any shortness of breath/signs of respiratory distress? History of genetic conditions? ii. Questions for ROS Poor feeding? Any newborn cardiac concerns? Previous cardiac history? Any pain, weakness, coldness to the extremities? Fluid retention? Cough

Health & Medical Capital Budgeting at Cleveland Clinic Nursing Assignment Help

Respond to each of the following prompts or questions: Using the information provided in the Los Reyes Hospital case study from Module Three, what capital expenditures may the selected departments need to budget? Considering the organization you selected, what is a capital expenditure that may be needed that would result

NVCC Service Implementation and Elements of Financial Nursing Assignment Help

Instructions: Part 1 1.Read Chapter 10, Capko. -Critique either Dr. Grainger’s or Mid-South Pulmomary Specialists efforts in developing  new services. -What lessons did you learn as related to new service development?   -List three main items which you must address before implementing a new service.  Instructions: Part 2 -The physicians

Healthcare is reimbursed in a variety of ways. The Nursing Assignment Help

Healthcare is reimbursed in a variety of ways. The prospective payment method is one of those ways. This paper will be about the prospective payment method where diagnosis-related groupings (DRGs) forms the basis for payment. Research and explain the origin, purpose, and description of DRGs. Include what payment is based on.

NUR 630 FIU Impact on Healthcare Systems and Public Health Nursing Assignment Help

Autism Spectrum Disorder, Intellectual Disabilities, or Childhood-Onset Schizophrenia In recent years, there have been reports linking autism to vaccinations. After studying Module 5: Lecture Materials & Resources, address the following in a well-written discussion post: Explain the controversy regarding vaccines as a possible cause of autism spectrum disorder. Does the

FIU Ambiguity and Doubts About Managing ASD Reflection Nursing Assignment Help

Autism Spectrum Disorder, Intellectual Disabilities, and Childhood-Onset Schizophrenia After studying Module 5: Lecture Materials & Resources, discuss the following: Reflect on your experience creating a treatment plan for a toddler, school-aged child, or adolescent with autism or an intellectual disability.  Describe the clinical situation in detail.  (Who was it, when